Detection, Isolation, and Characterization of Plasmids in the Environment
ChapterPlasmids play a major role in the bacterial adaptation to changing and stressful environmental conditions caused by antibiotics, heavy metals, and disinfectants. However, the investigation of the ecology and diversity of environmental plasmids is challenging due to their typically low abundance in soil bacterial communities and the low cultivability of their hosts. Here we discuss the potentials and limitations of cultivation-dependent and cultivation-independent approaches for detecting and quantifying plasmids in total community DNA from environmental samples. Protocols for PCR-based detection of plasmid-specific sequences in total community DNA are presented. Furthermore, protocols to obtain and characterize plasmids either from isolates (endogenous plasmid isolation) or by capturing into a recipient strain by biparental and triparental mating will be provided.
Khald Blau, (10-2020), USA: Methods in Molecular Biology, 39-60
Colistin-resistant Enterobacteriaceae isolated from process waters and wastewater from German poultry and pig slaugtherhouses
Journal ArticleDue to the high prevalence of colistin-resistant Enterobacteriaceae in poultry and pigs, process waters and wastewater from slaughterhouses were considered as a hotspot for isolates carrying plasmid-encoded, mobilizable colistin resistances (mcr genes). Thus, questions on the effectiveness of wastewater treatment in in-house and municipal wastewater treatment plants (WWTPs) as well as on the diversity of the prevailing isolates, plasmid types, and their transmissibility arise. Process waters and wastewater accruing in the delivery and unclean areas of two poultry and two pig slaughterhouses were screened for the presence of target colistin-resistant bacteria (i.e., Escherichia coli, Klebsiella spp., Enterobacter cloacae complex). In-house and municipal WWTPs (mWWTPs) including receiving waterbodies were investigated as well. Samples taken in the poultry slaughterhouses yielded the highest occurrence of target colistin-resistant Enterobacteriaceae (40.2%, 33/82), followed by mWWTPs (25.0%, 9/36) and pig slaughterhouses (14.9%, 10/67). Recovered isolates exhibited various resistance patterns. The resistance rates using epidemiological cut-off values were higher in comparison to those obtained with clinical breakpoints. Noteworthy, MCR-1-producing Klebsiella pneumoniae and E. coli were detected in scalding waters and preflooders of mWWTPs. A total of 70.8% (46/65) of E. coli and 20.6% (7/34) of K. pneumoniae isolates carried mcr-1 on a variety of transferable plasmids with incompatibility groups IncI1, IncHI2, IncX4, IncF, and IncI2 ranging between 30 and 360 kb. The analyzed isolates carrying mcr-1 on transferable plasmids (n = 53) exhibited a broad diversity, as they were assigned to 25 different XbaI profiles. Interestingly, in the majority of colistin-resistant mcr-negative E. coli and K. pneumoniae isolates non-synonymous polymorphisms in pmrAB were detected. Our findings demonstrated high occurrence of colistin-resistant E. coli and K. pneumoniae carrying mcr-1 on transferrable plasmids in poultry and pig slaughterhouses and indicate their dissemination into surface water.
Khald Blau, (10-2020), UK: Frontiers in Microbiology, 11 (2699), 1-18
دور إدارة الموارد البشرية في وظيفة التوظيف( دراسة استطلاعية تحليلية بمصرف الجمهورية فرع القواسم)
مقال في مؤتمر علمي.
عماد رمضان عمر عمار، نوري خليفة عثمان خليفة، (10-2020)، نيجيريا: 2nd International African Conference On Current Studies، 74-84
Hybrid CHP/Geothermal Borehole System for Multi-Family Building in Heating Dominated Climates
Journal ArticleAbstract: A conventional ground-coupled heat pump (GCHP) can be used to supplement heat
rejection or extraction, creating a hybrid system that is cost-eective for certainly unbalanced climes.
This research explores the possibility for a hybrid GCHP to use excess heat from a combined heat
power (CHP) unit of natural gas in a heating-dominated environment for smart cities. A design for
a multi-family residential building is considered, with a CHP sized to meet the average electrical
load of the building. The constant electric output of the CHP is used directly, stored for later use in a
battery, or sold back to the grid. Part of the thermal output provides the building with hot water,
and the rest is channeled into the GCHP borehole array to support the building’s large heating needs.
Consumption and weather data are used to predict hourly loads over a year for a specific multi-family
residence. Simulations of the energies exchanged between system components are performed, and a
cost model is minimized over CHP size, battery storage capacity, number of boreholes, and depth of
the borehole. Results indicate a greater cost advantage for the design in a severely heated (Canada)
climate than in a moderately imbalanced (Ohio) climate.
Saeed Alqaed, Jawed Mustafa, Kevin P. Hallinan, Rodwan Elhashmi, (09-2020), Sustainability: MDPI, 12 (18),
Mie MODEL OF RADIATION HEAT TRANSFERIN ISOTHERMAL SPHERICAL MEDIUM
Journal ArticleIn certain extremely low probability, severe accident scenarios which have been postulated for liquid metal cooled fast reactors,large bubble cavities containing fuel vapor and fission products transit a layer of coolant and release this material to the cover gas thereby presenting a contribution to an accident-specific source term [5].Mie model in radiation heat transfer has been investigated to analysis and interpret the experiments that conducted during 1980's for oxide UO 2 fueled reactors in Fuel Aerosol Simulant Test (FAST) facility at Oak Ridge National Laboratory (ORNL).These analyses are applied to estimate the bubble collapse of Liquid Metal reactors (LMR's) during a hypothetical core disruptive accident (HCDA).InMie scattering model the particle size was 0.07 µm [6]. The scattering coefficient of UO 2 particles (σ = 1.24 m-1), was calculated by using Mie theory,at the same number of stable nuclei's N (2.9 E15 nuclei/m 3) that resulted from theabsorbed coefficientk = 0.082 m-1 [7].P 1 approximation method was used to solve the radiative heat transfer equation (RTE) in spherical coordinates of participating medium confined between the two concentric spheres.The surfaces of the spheres are assumed to be gray, diffusely emitting and diffusely reflecting boundaries, and an isothermal boundary conditions were assumed at these surfaces.Marsak's boundary condition was to computed, the net radiative heat flux q(τ), and the incident radiation G(τ), to analyze and interpret the CVD experiments data that were conducted in the FAST facility at ORNL [8] and Fast Flux Test Facility reactor (FFTF) in Argonne National Laboratory ANL.The conclude that extracted from this study is greater margin of safety when the bubble rising time is greater than the bubble collapse time since the bubble collapses (UO 2 condenses) before it can reach the top of the vessel therefore there is less chance of release of aerosol as in Oak Ridge National Laboratory (ORNL) FAST experiments and Argonne National Laboratory (FFTF) reactor.
Hmza Ashur Milad Mohamed, (09-2020), USA: IJSRED, 3 (5), 402-420
Rayleigh Model of Radiation Heat Transfer in Spherical Medium
Journal ArticleIn certain extremely low probability, severe accident scenarios which have been postulated for liquid metal cooled fast reactors, large bubble cavities containing fuel vapor and fission products transit a layer of coolant and release this material to the cover gas thereby presenting a contribution to an accident-specific source term [5]. Rayleigh model in radiation heat transfer has been investigated to analysis and interpret the experiments that conducted during 1980's for oxide UO 2 fueled reactors in Fuel Aerosol Simulant Test (FAST) facility at Oak Ridge National Laboratory (ORNL).These analyses are applied to estimate the bubble collapse of Liquid Metal reactors (LMR's) during a hypothetical core disruptive accident (HCDA). In Rayleigh non-scattering model the particle size was 0.01 µm [6],and according to Mie theory principle, the absorption coefficient for small particle-size distribution was estimated (k = 10 m-1 was used) from reference [7] at complex refractive index of UO 2 at λ = 600 µm and x = 0.0785.A MATLAB code was used to solvethe radiative heat equation (RTE) in spherical coordinates. The mixture is in local thermodynamic equilibrium inside the bubble which has a black body surface boundary.The mixture in the cavity contains three components: the non-condensable gas Xenon, Uranium dioxide vapor, and fog.To simulate fuel bubble's geometry as realistically as possible, according to experimental observation, the energy equation in a spherical coordinate system has been solved with the radiative flux heat transfer equation (RTE) to obtain the effect of fuel bubble's geometry on the transient radiative heat flux and to predict the transient temperature distribution in the participating medium during a hypothetical core disruptive accident (HCDA) for liquid metal fast breeding reactor (LMFBR) for FAST. The transient temperature distribution in fog region was utilized to predict the amount of condensable UO 2 vapor = − ! " ! #. The conclusion that can be drawn from the present study, is that the Fuel Aerosol Simulant Test (FAST) facility at Oak Ridge National Laboratory has a larger margin of safety since the bubble rising time is greater than the bubble collapse time.
Hmza Ashur Milad Mohamed, (09-2020), USA: IJSRED, 3 (5), 421-437
Low-energy opportunity for multi-family residences: A review and simulation-based study of a solar borehole thermal energy storage system
Journal ArticleThe multi-family residential building sector is the least energy efficient in the United States, thus allowing for ample opportunities for significant cost-effective energy and carbon savings. In the present study, we propose a district solar borehole thermal solar energy storage (BTES) system for both retrofit and new construction for a multi-family residence in the Midwestern United States, where the climate is moderately cold with very warm summers. Actual apartment interval power and water demand data was mined and used to estimate unit level hourly space and water heating demands, which was subsequently used to design a cost-optimal BTES system. Using a dynamic simulation model to predict the system performance over a 25-year period, a parametric study was conducted that varied the sizes of the BTES system and the solar collector array. A life-cycle cost analysis concluded that is it possible for an optimally-sized system to achieve an internal rate of return (IRR) of 11%, while reducing apartment-wide energy and carbon consumption by 46%. Both a stand-alone and solar-assisted ground-source heat pump system were designed and simulated for comparison to the BTES system, and found to be less economically favorable than the solar BTES system. Thus, the promise for district-scale adoption of BTES in multi-family residences is established, particularly for new buildings.
Rodwan Elhashmi, Kevin P. Hallinan, Andrew D. Chiasson, (08-2020), Energy: Pergamon, 204
Floristic Study of Sedrores Mountains in Gharyan District–Libya
Journal ArticleA floristic survey of Sedrores Al-Qawasim mountains in Gharyan district - Libya was conducted in two consecutive growing seasons from 01/04/2018 to 01/6/2019. In this study area, a total number of 320 plant species belonging to 214 genera were collected representing 44 families, of which 39 families and 276 species belonging to dicotyledons, and 5 families and 44 species are belonging to monocotyledons. The results showed the dominance of the family Asteraceae with 60 species, followed by the family Fabaceae with 32 species, then the family Poaceae with 29 species. The results showed the dominance of the (Euphorbia genus) with 7 species, followed by Helianthenum, Plantago and Erodium with 6 species each. Moreover, life-form spectrum analysis showed the predominance of therophytes with 210, followed by Hemicryptophytes with 59 species, while chorotype spectrum analysis showed the dominance of Mediterranian species with 151 species, followed by Mediterrean/Iranu-Turanean with 72 species.
Shhoob Mohamed imhmed Elahmir, Mohammed H. Mahklouf, Mahmood B. Shanta, Hisham Ali Abo -Jaafer, (07-2020), كندا: J. of Advanced Botany and Zoology, 1 (8), 1-10
Parametric modeling and simulation of Low temperature energy storage for cold-climate multi-family residences using a geothermal heat pump system with integrated phase change material storage tank
Journal ArticleA novel geothermal heat pump (GHP) system with an integrated low- to moderate-temperature salt hydrate phase change material (PCM) storage tank for buildings in cold climates is proposed in this study. The purpose of the PCM storage tank is to dampen peak heating loads and to remove annual ground thermal load imbalances on the ground heat exchanger (GHX) to assist in achieving an optimally-sized GHX. As heat is extracted from the closed-loop system by heat pumps in heating mode, a significant portion of this heat is used to solidify a salt hydrate PCM. This heat of fusion is later released back into the heat transfer fluid, storing it in the PCM tank and GHX for later diurnal and seasonal use. To examine the merits of the proposed concept, electric utility meter data on 15-minute time intervals were mined from an actual apartment building and used to estimate space heating, cooling, and hot water heating loads. Those data were used in an hourly, dynamic 20-year life-cycle simulation model in TRNSYS to design an optimum combination of GHX and PCM storage, where each component was sized to balance the annual ground thermal loads. The system simulation results show significant potential for GHX size reduction with a PCM storage tank, but the system is quite sensitive to the PCM melt temperature due to significant hysteretic nature of the salt hydrate PCM heating and cooling curves. We also find that there is no unique optimum unless other factors are considered such as installation cost and physical constraints; many combinations of GHX size and PCM mass are capable of achieving the design goal with similar annual electric energy consumption. For the cases examined here, a PCM melt temperature of 27 °C yields the most favorable economic results, and a preliminary economic analysis suggests that with typical drilling cost and PCM tank cost values, the GHX size can be reduced by over 50 %.
A. Alkhwildi, R. Elhashmi, A. Chiasson, (07-2020), Geothermics: Pergamon, 86 (32767),
القدرة العضلية للذراعين وعلاقتها بدقة أداء مهارتي الإرسال من أعلي والضرب الساحق في الكرة الطائرة